The portable mass-flow Controller (MF-1000) has been developed to ensure the use of SF6 gas is accurately controlled and monitored. SF6 gas is an expensive commodity which can also have a major environmental impact when released into the atmosphere. Governments worldwide are introducing legislation, such as EC842/2006, to control the use of this gas and limit leaks from the equipment in which it’s
Unit available in two formats: 15kg/hr for “top-up” and 50kg/hr for “fill” operations. |
Ease-of-use |
Automatic data |
Automatic data |
Description
The portable mass-flow Controller (MF-1000) has been developed to ensure the use of SF6 gas is accurately controlled and monitored. SF6 gas is an expensive commodity which can also have a major environmental impact when released into the atmosphere. Governments worldwide are introducing legislation, such as EC842/2006, to control the use of this gas and limit leaks from the equipment in which it’s used as an insulating medium. Therefore accurate measurement and control of SF6 usage, is essential.
The MF-1000 is a fully automatic portable mass-flow controller which can monitor and record how much gas is being used during both “fill” and “top-up” operations. The key features and accuracy of this instrument offer a major step forward in the handling of SF6 gas within the electricity market.
Features
Specifications
Flow Ranges: 0.5 to 15kg/hr or 2 to 50 kg/hr
Gas Pressure: 500psig maximum, Burst Tested to 750psig
Accuracy: Std Calibration ±1% of full scale at operating conditions High Accuracy Calibration ± 0.7% of reading plus 0.3% of full scale at operating conditions
Repeatability: ± 0.2% of scale
Temperature Coefficient: ± 0.025% of full scale per oF
Pressure Coefficient: ± 0.01% of full scale per psi
Response Time: 300 milli-second time constant: 2 seconds (typical) to within ±2% of final value (includes setting time)
Gas & Ambient Temperature: 0oC to 50oC
Application