iSF6-516 PRO SF6 Gas Collecting & Recycling Unit

iSF6-516 PRO SF6 Gas Collecting & Recycling Unit

Description

Collecting used SF6 gas is vital and compulsory. EU and IEEE have published codes on elimination of SF6 gas emission. iSF6-516 PRO is designed for collecting and recycling used SF6 gas from SF6 analyzers. The unit is contained in a robust waterproof ABS trolley case.

Features
SF6 used gas zero emission
Compatible to different types of SF6 analyzers
Fully automatic with reliability
Fully automatic with reliability

Description

The electricity generating and distribution industry are making use of the insulating properties of SF6 to replace the oils and vacuums currently used as insulators. Normally SF6 is totally inert but being the reaction with water in the presence of an electrical discharge in high-voltage equipment, it can breakdown to form decomposed byproducts. These corrosive byproducts react with the materials of construction to produce metal fluorides which, in addition to producing a general reduction in performance, cause problems by settling as electrically conducting particles on eletrical contacts. It’ll irritate/injure noses, mouths, eyes or skins if people get in contact with these byproducts accidentally. Incidents of human poisoning by inhale SF6 emission have been reported from certain Prevention and Treatment Centers of Occupational Diseases globally.


SF6 is a well-known greenhouse gas, due in part to its atmospheric lifetime of 3200 years and its global warming potential is 23900 times greater than that of CO2. Due to its destructive potential SF6 gas was included in the Kyoto Protocol under which emission reduction targets apply.


Collecting used SF6 gas is vital and compulsory. EU and IEEE have published codes on elimination of SF6 gas emission. iSF6-516 PRO is designed for collecting and recycling used SF6 gas from SF6 analyzers. The unit is contained in a robust waterproof ABS trolley case.


Features

  • 5” color touch screen
  • iSF6-516 PRO is connected with one instrument. The used SF6 gas can be collected via a gas compressor through the following method.

a.  Collect and store used SF6 gas in an on-board vessel. The stored gas can be transferred to an external cylinder after several tests or whenever necessary.

b.  Collect gas and store in an external cylinder.

c.  Pump back stored gas to the equipment (9 bar) under permission and certain circumstances to achieve zero emission of SF6 gas.


Parameters

5” color touch screen

0.8m3/h compressor, final pressure 10bar

Connecting hose to transfer SF6 gas from the instrument

Swagelok connectors apply

  • gas chamber
  • instrument inlet
  • instrument outlet
  • external cylinder

Onboard vessel (50bar)

Swagelok self-sealing couplings

Acoustic and visual alarm in auto control module

Compressor monitor timer

Overload protection

Mains power module

Power supply: 220-240VAC 50/60Hz

Dimension: 493×466×286mm


Accessories

1pc 6m armoured sampling tube including DN8 and DN20 couplings

1pc 3m armoured sampling tube including self-sealing couplings

1pc 3m FEP sampling tube including quick connectors

1pc 2m rubber hose including cylinder connectors


Options

1kit all kinds of connectors applicable to different analyzers


Call technical support for using iSF6-516 PRO with other non-standard instruments.