TE-660 Dew point transmitter with a measuring range down to -60°C dp is ideal for applications in compressed air systems, plastic dryers and industrial drying processes. An integrated auto-calibration procedure permits a measurement accuracy of <2 °Cdp. The measured values for dew point is available on an analog 4-20 mA. Integration into the measurement task is simplified by the compact d
Fully calibrated at TEKHNE factory |
Innovated Polymer technology |
Measuring range:-60 to +20 ℃ dp |
Measuring range:-60 to +20 ℃ dp |
Introduction
TE-660 Dew point transmitter with a measuring range down to -60°C dp is ideal for applications in compressed air systems, plastic dryers and industrial drying processes. An integrated auto-calibration procedure permits a measurement accuracy of <2 °Cdp.
The measured values for dew point is available on an analog 4-20 mA. Integration into the measurement task is simplified by the compact design and the exceptionally robust stainless steel housing.
Application
refrigerant type dryer
absorption dryer
plastics dryer
Installing
If installing directly into the process, a stop valve should be at both sides of the installation point. This makes it easy to remove the transmitter for maintenance and calibration.
Monitor for TE-660 On-line
If power supply and display are required, TK-100 On-line monitor is included in TK-660 On-line.
Technical Specifications
TE-660 Transmitter
Measurement range -60 to 20 °Cdp
Accuracy ±2 °Cdp (at 25 °C)
Response time t90 < 5 min (-20 °Cdp0-60 °Cdp)
< 15 sec (-60 °Cdp0-20 °Cdp)
Analog output 4-20 mA(3-wire technology) RL < 500 Ohm
Resolution of analog output 2 μA
Temperature dependence ±5ppm of the measuring span / °C (Deviating from 20 °C)
Power supply 18 to 28 VDC
Power consumption at 24VDC <20mA + load current
with auto calibration: 100 mA + load current
Operating pressure Up to 8 MPa
Electrical connection M12 x1 5-pin plug
Sensor protection Stainless steel sintered filter
Temperature/humidity operating range -40 to 70 °C / 0 to 100 %RH
Storage temperature -40 to 60 °C
Electromagnetic compatibility EN61326-1 EN61326-2-3 Industrial environment
FCC Part 15 ICES-003 ClassB
Monitor for TE-660 On-line
Display 5 digit LED
Measurement Ranges -60 to 20 °Cdp
Outputs 4-20 mA
Alarm Relays 3 relay contact
Operating environment 0 to +50 °C (35 to 85 %RH)
Storage environment -10 to +70 °C (max 60 %RH)
Power supply 100 to 240 VAC, 50/60 Hz
Sensor cable Cable, screened twisted pair (x2), 7/0.2 type 1, common drain. (Max length 1,000 m)